How does the nitrogen sealing system of the storage tank cooperate with the solvent recovery? The core is the four words of "replenishing and replenishing": when the liquid level in the tank drops or the temperature drops, the nitrogen sealing valve automatically replenishes nitrogen to maintain a slight positive pressure to prevent air intake; when the liquid level rises or the temperature rises, the gas in the tank is discharged from the breathing port, and the exhaled gas is connected to the collection branch pipe for condensation recovery, and recovery, so that the solvent vapor becomes the raw material rather than the discharge. Nitrogen sealing and recycling are two sides of the same set of tank farm logic. Only when they are designed together can there be no loopholes.
The micro-positive pressure of the nitrogen seal separates the air in the tank from the outside, the oxygen content is depressed, and the risk of explosion decreases accordingly. For hygroscopic or easily oxidized solvents, it can also slow down moisture absorption and deterioration, and the quality of the recovered liquid is more guaranteed. The nitrogen sealing valve is automatically opened and closed according to the pressure in the tank, and the breathing valve is used as the bottom protection for overpressure and negative pressure. The division of labor between the two is clear: the nitrogen sealing and collection pipeline are used for daily breathing, and it is the breathing valve's turn to act under abnormal working conditions.
Exhaled breath is led out from the breathing port on the top of the tank, and then connected to the collection branch pipe through the fire resistance facility. When multiple storage tanks are connected to the main pipe, the simultaneous use coefficient shall be approved. The branch pipe shall maintain the slope and set a low point to discharge liquid to prevent the accumulation of condensate. The exhaled volume is large under the receiving condition, and the discharging condition is supplemented by nitrogen sealing. The gas volume images of the two paths are quite different. The recovery device is configured according to the peak condition, and the buffer tank spreads out the fluctuation. See the following table for the division of the gas paths in the tank farm:

| Airway | Operating condition | Configuration Requirements |
|---|---|---|
| Nitrogen supplement road | Trend of negative pressure in the tank caused by feeding and cooling | Nitrogen seal valve automatically replenish pressure, filtration and decompression are complete |
| Exhaled recycling road | Positive pressure trend in the tank caused by material collection and temperature rise | Fire retardant plus lead pipe, connected to condensate recovery |
| Breather valve | Abnormal overpressure or negative pressure conditions | Fixed pressure inspection, action record filing |
| Condensate road | Condensate recovered and transported in a closed manner, and registered as per batch | |
What needs to be checked in particular is the matching between the pumping force of the recovery system and the pressure in the tank: the collection fan pumps the main pipe into negative pressure to bleed air, the single tank lead pipe shall have limited flow or balance measures, and the pressure in the tank shall always be kept in the normal range, which is the joint where the nitrogen seal and recovery linkage is most likely to cause problems, and the debugging phase shall be verified tank by tank.
The nitrogen seal side stares at three things: nitrogen seal valve action record, nitrogen supply pressure and breathing valve fixed inspection, and the ability to cover the bottom must be available at any time; The recovery side stares at the negative pressure and condensate volume of the main pipe. The data on both sides are put into the same daily report of the tank farm. When the loss trend of the tank farm changes suddenly, the nitrogen seal and recovery are checked together, and the attribution is not disassembled. In rainy season and season with large temperature difference, the patrol inspection shall be encrypted to prevent the breathing valve from freezing and sticking.
The breathing of receiving and sending materials and the temperature difference between day and night is normal. The sudden frequency amplification first checks the pipeline leakage and set pressure, eliminates external factors and then checks the nitrogen sealing valve itself. The action record is the basic data for judgment.
Want. Nitrogen sealing valve is responsible for daily micro-positive pressure adjustment. Breathing valve is the protection of overpressure and negative pressure. The division of labor is not a substitute. The breathing valve is regularly checked and the pressure is guaranteed to be available at any time.
The concentration of exhaled breath fluctuates with the working conditions, and the concentration during the receiving period is considerable, and the cumulative amount over the years is not small. Moreover, after being connected to the recovery, the unorganized discharge in the tank farm will be eliminated simultaneously, which will benefit both environmental protection and materials, and will be evaluated according to the medium and turnover.
Luoyang wohong petrochemical equipment co., ltd. provides design, installation, commissioning and operation and maintenance services for the linkage transformation of nitrogen seal and solvent recovery in tank farm. welcome to contact and exchange.
This article is organized by Luoyang wohong petrochemical equipment co., ltd. if you need tank farm recovery and renovation assessment or on-site investigation, please contact and exchange.
Company Name:
Luoyang Wohong Petrochemical Equipment Co., Ltd
Hotline:
13526990215
Company Address:
W2-1, Dongda Technology Industrial Park, Luoxin Industrial Cluster, Xin'an County, Luoyang City
E-mail
lixiang@vohonoilpipe.com
Scan to follow us
Luoyang Wohong Petrochemical Equipment Co., Ltd Powered by EyouCms Henan ICP Registration No. 17014668-11 sitemap.xml